OLCT 60 - Fixed gas detector

OLCT 60 - Fixed gas detector

OLCT 60 - Industrial Gas Detector

  • 4-20 mA analog transmitter with display
  • Detects O2, combustible, toxic and refrigerant gases
  • Corrosion resistant
  • Designed for industrial applications
  • Available with remote sensor head, flameproof or intrinsic safety versions
  • Non-intrusive, one-man calibration
  • XP IR infrared sensor for combustible gases or CO2

The OLCT 60 is a generation of high quality gas detectors which covers all industrial needs for a variety of applications.

The OLCT 60 Series is composed of several versions:

  • XP or IS sensor (toxic or oxygen versions)
  • Remote or on-board sensor.

The OLCT 60AD version allows the sensor to be installed remotely up to 15 meters (standard), allowing detection in inaccessible locations, or in Zone 0 in the case of the intrinsically safe (IS) version. The detector units are made of 316L stainless steel, and are rugged and resistant to corrosion. Pre-calibrated sensors can be disconnected by turning the head of the unit. These “smart” sensors can be calibrated outside hazardous areas.

The OLCT 60 is equipped with non-intrusive access to a safe menu. In hazardous areas, calibration can be done with an operating mode in accordance with safety rules.

  • Access to maintenance menu
  • Pure air injection
  • Zero validation*
  • Standard gas injection
  • Calibration validation taking into account the usage rate*

All of these tasks can be carried out without opening the detector, using a unique magnetic key. Access to the maintenance mode is protected to avoid accidental reprogramming of the unit.

​​​​​* Automatic adjustment of zero and sensitivity​​

Documentation

Commercial Brochure - English

User Manual - English

Certifications

Certification Description
ATEX A product regulation which ensures the safety of equipment intended for use in potentially explosive atmospheres in the European Union.
CE indicates that a product has been assessed by the manufacturer and deemed to meet EU safety, health and environmental protection requirements.
China Ex Testing and certifications providers in China
EAC Gost R and EAC certifications are mandatory in order to have access at all to the Russian market and the markets of the five EAC members

 

Gases

Symbol Description Toxic Gas
AsH₃ Arsine Gas Detectors  
C₂H₂ Acetylene  
C₂H₄ Ethylene  
C₂H₄O Ethylene Oxide  
C₂H₆ Ethane  
C₂H₆O Ethanol  
C₃H₆ Propylene  
C₃H₆O Acetone  
C₃H₈ Propane  
C₃H₈O Isopropyl Alcohol  
C₄H₁₀ Butane  
C₄H₁₀O Isobutanol  
C₄H₆ Butadiene  
C₄H₈O Methyl Ethyl Ketone (MEK)  
C₅H₁₂ Pentane  
C₆H₁₄ Hexane  
C₆H₆ Benzene  
C₇H₈ Toluene  
C₈H₁₀ Xylene  
CH₂O Formaldehyde  
CH₃I Methyl Iodide  
CH₃SH Methyl Mercaptan  
CH₄ Methane Gas Detectors  
CH₄S Methyl Mercaptan  
Cl₂ Chlorine  
ClO₂ Chlorine Dioxide  
CO Carbon Monoxide  
CO/H₂ Carbon Monoxide / Hydrogen  
CO₂ Carbon Dioxide  
Combustible % LEL Combustible Percent Lower Explosive Limit (LEL)  
F₂ Fluorine  
GEH₄ Germane  
H₂ Hydrogen  
H₂S Hydrogen Sulfide  
HBr Hydrogen Bromide  
HCl Hydrogen Chloride  
HCN Hydrogen Cyanide  
HF Hydrogen Fluoride  
N₂H₄ Hydrazine  
NH₃ Ammonia  
NO Nitric Oxide  
NO₂ Nitrogen Dioxide  
O₂ Oxygen  
O₃ Ozone  
PH₃ Phosphine  
SiH₄ Silane  
SO₂ Sulfur Dioxide  
VOC Volatile Organic Compound  
OLCT 60 - Fixed gas detector